Sobieski 21-Point Inspection
-
A/C or Heat PumpCheck and level TSAT
Replace standard air filter
Clear condensate line
Check temp rise / drop
Clean blower vents
Check blower amp readings
Check blower capacitor
Check electric heat strips (Heating mode only)
Clean condenser coils (Cooling mode only)
Clean debris from outdoor unit
Clean oxidation from outdoor unit cover
Check refrigerant levels
Clean super heat and subcooling
Check contactor for pitting
Check outdoors capacitors
Clean electrical compartment
Check and tighten electrical connections
Check outdoor motor bearings
Check amp readings on compressor and outdoor motor
Compressor meg readings
Check disconnect box
-
Gas FurnaceClean furnace compartment
Clean furnace casing
Clean and check flame sensor
Check and test igniter / pilot
Replace standard style air filter
Check furnace safety controls
Check blower capacitor
Check motor amp readings
Check blower capacitor (Note: This is repeated on the original list)
Check blower speed
Check motor vents
Check heat exchanger for cracks
Pill blower motor assemble to access heat exchanger (80% heaters only)
Check combustion reading
Check temp rise against manufacturer specs
Check gas pressure
Check and level TSAT
Visual inspection of burners
Clear condensate trap (90% heaters only)
Check and tighten electrical connections
Check for flue obstruction and proper venting
-
BoilersPull and clean burner tubes
Clean boiler cabinet
Clean burner compartment
Check igniter / pilot
Clean and check flame sensor / thermocouple
Check combustion readings
Check safety switches and controls
Check and tighten electrical connections
Check water temp
Check water pressure
Check and drain expansion tank
Visual inspection for water leaks
Check and adjust gas pressure
Check and lube circulator
Check flue for obstructions and proper venting
Check to see if all rooms are heating
Check for air in the lines
Check and level TSAT
Check heat exchanger for leaks
Check zone values
Check auto vents
-
Oil FurnaceReplace oil filter
Replace air filter
Replace pump strainer
Replace oil nozzle
Adjust electrodes
Check and adjust pump pressure
Clean vents on air band
Adjust air band settings
Clean furnace cabinet
Clean furnace casing
Check combustion readings
Check safety switches and controls
Check and tighten electrical connections
Check blower amp readings
Check blower vents
Check blower capacity
Check temp rise
Check heat exchanger for cracks
Check flue for obstructions and proper venting
Vacuum flue breach
Check and level TSAT
Hear From Our Happy Customers
-
“I would 100% recommend this company.”Julie L.
-
“Sobieski has become our regular call for plumbing service.”Gary M.
-
“Hector understands the true meaning of customer service and id be happy to have him back.”Amara D.
Trusted In Our Industry
With our service partner plan, trust that Sobieski has your back. Enjoy the peace of mind of knowing you’re not only preventing early system failure, but that your system is operating at peak efficiency while keeping utility bills as low as possible!